Difference between revisions of "MEDITECH Interface Manager"

From Galen Healthcare Solutions - Allscripts TouchWorks EHR Wiki
Jump to navigation Jump to search
Line 2: Line 2:
 
Native client-side application used to configured and manage MEDITECH endpoint to send and receive information between MEDITECH and outside vendor (OV) systems.
 
Native client-side application used to configured and manage MEDITECH endpoint to send and receive information between MEDITECH and outside vendor (OV) systems.
 
=FAQ=
 
=FAQ=
 +
==Q: How do I filter outbound results based on location?==
 +
A: Leveraging a toolbox parameter in the message generator dictionary, MEDITECH can filter the results by location through a lookup.
 +
==Q: How are child susceptibilities linked to the identified organizations in a HL7 microbiology result message?==
 +
A: OBR.26 is used to link the susceptibility procedures to the organisms. OBR.26.1 contains the Observation ID and OBR.26.2 contains the Observation Sub-ID. The combination of those two values uniquely identifies which organism the susceptibility procedure is linked to.
 +
==Q: What would prevent results from sending to the OV interface?===
 +
A: Check the LIS Lab Site configuration to ensure the outbound LAB/MIC/BBK/PTH Results to OV interface is linked to an LIS Labs Site as defined on page 3 of the LIS Lab Site Dictionary (Ancillary->Laboratory->Dictionaries->LIS A-L->Lab Site->Enter/Edit).
 +
==Q: What causes “Unable to open active socket” in MEDITECH interface manager?==
 +
A: This error is commonly associated with connectivity issues to the OV system. Ensure the OV system is set to listen on the IP/port defined and check for firewall rules that may be blocking connection on the IP/port. To troubleshoot, toggle the delivery service background job within Interface Manager.

Revision as of 18:07, 30 August 2016

Overview

Native client-side application used to configured and manage MEDITECH endpoint to send and receive information between MEDITECH and outside vendor (OV) systems.

FAQ

Q: How do I filter outbound results based on location?

A: Leveraging a toolbox parameter in the message generator dictionary, MEDITECH can filter the results by location through a lookup.

Q: How are child susceptibilities linked to the identified organizations in a HL7 microbiology result message?

A: OBR.26 is used to link the susceptibility procedures to the organisms. OBR.26.1 contains the Observation ID and OBR.26.2 contains the Observation Sub-ID. The combination of those two values uniquely identifies which organism the susceptibility procedure is linked to.

Q: What would prevent results from sending to the OV interface?=

A: Check the LIS Lab Site configuration to ensure the outbound LAB/MIC/BBK/PTH Results to OV interface is linked to an LIS Labs Site as defined on page 3 of the LIS Lab Site Dictionary (Ancillary->Laboratory->Dictionaries->LIS A-L->Lab Site->Enter/Edit).

Q: What causes “Unable to open active socket” in MEDITECH interface manager?

A: This error is commonly associated with connectivity issues to the OV system. Ensure the OV system is set to listen on the IP/port defined and check for firewall rules that may be blocking connection on the IP/port. To troubleshoot, toggle the delivery service background job within Interface Manager.