==Description==
 +
The 'OrderResults-v11' content category allows you to define your orderable and resultable items and establish the appropriate relationship between them.  Some orderable items such as labs may have one or more resultable items associated with them and some orderable items such as radiology typically have only one resultable item associated with them.  The 'OrderResults-v11' content category allows you to set some basic context and populate some main fields associated with both orderable and resultable items.  It is a key category that will help create the foundation for your Orderable Item dictionary and is typically derived from a compendium extract provided by your LIS, RIS, 3rd party lab vendor, or any diagnostic system that will be sending results or receiving orders from EHR.
  
 +
'''Stored Procedures used''':
 +
* Extracting data: ImpGetOrderANDResult
 +
* Loading data: ImpSetOrderAndResults
  
 +
==Column Listing and Description==
 +
 +
*'''Order Code''' - this is the unique identifier for the orderable item and is limited to 10 characters (alpha-numeric).  The order code is typically the primary identifier used for inbound result interface matching and outbound order matching so be sure to honor the codes supplied to you by our LIS, RIS, or other 3rd party lab vendor.  If the test is being built as an In Office test or not referenced in any interface then you may define your own naming convention for this field.
 +
 +
    Storage Location:  Works.dbo.Qo_Classification_DE.EntryCode
 +
    Data Type:  VarChar(10)
 +
    Possible Values:  Free Text
 +
 +
*'''Order Name''' - this is the name of the orderable item and if no display name is defined in the [[SSMT: OID - Orderable Item Dictionary |OID - Orderable Item Dictionary ]] then this will also function as the name displayed in the EHR.
 +
 +
    Storage Location:  Works.dbo.Qo_Classification_DE.EntryName
 +
    Data Type:  VarChar(255)
 +
    Possible Values:  Free Text
 +
 +
*'''Order Mnemonic''' - this is also limited to 10 characters (alpha-numeric) and some external lab vendors actually define a short and meaningful alpha description for it.  If ever given only a code for an orderable item it is best practice to have the mnemonic value mirror the entry code value.
 +
 +
    Storage Location:  Works.dbo.Qo_Classification_DE.EntryMnemonic
 +
    Data Type:  VarChar(10)
 +
    Possible Values:  Free Text
 +
 +
*'''OrderingAuthority''' - this field designates a numeric value (1-10) and functions as an authentication value for ordering specific tests.  The user must have an ordering authority set equal to or greater than that of the test in order to order the test. "1" is typically the default value for this field.
 +
 +
*'''OIDMode''' - this column is intended to define the current state of the orderable item.  Valid values for this field are:
 +
 +
    *  Active - This means the OID entry is active and available to users
 +
    *  Draft - This means that the OID entry is editable in the dictionary, but users cannot see the entry. 
 +
      This would be used if you were in the process of completing entries and didn't want them viewable.
 +
    *  No Longer Used - This essentially means it's inactive.
 +
 +
*'''OrderType''' - this field correlates to the pre-delivered categories available for classifying orderable items.  These values are basically the parent classes for the Parent Order Classification values (see below); they are the top levels in the OID hierarchy.
 +
 +
    *  Diagnostic Orders
 +
    *  Imaging
 +
    *  Supply
 +
    *  Referral Orders
 +
    *  Follow-Up Orders
 +
    *  Lab
 +
    *  Other
 +
    *  Findings
 +
    *  Patient Instructions
 +
    *  Patient Precautions
 +
 +
*'''Parent Order Classification''' - this field will determine where in the Orderable Item Dictionary's hierarchy the particular orderable item will be filed.  This might be CT if the test is a Diagnostic Image or may be Microbiology is the test is a culture.  One important consideration is that if you would like to store the orderable item in a classification or category that is not delivered with the system then it must exist prior to loading.  This column will match on the name of the classification.
 +
 +
*'''ItemType''' - for the purpose of loading your lab or rad compendium(s) this value should be set to "RESULTS".  Possible values include:
 +
 +
    *  RESULTS
 +
    *  FINDINGS
 +
    *  OTHERS
 +
 +
*'''OrderableSource''' - this column will allow you to set the method by which the orderable item can be created or ordered.  Valid values for this column are:
 +
 +
    *  User Only - This means that only a user can request the order
 +
    *  Interface Only -  This means that the order can only be requested from an interface transaction
 +
    *  User or Interface - This means that an Order can be requested by an interface transaction or a user
 +
    *  Recorded Only - This means that an Order can be documented only and would not be printed or sent to the interface
 +
 +
*'''DefReqPerfLocation''' - this field can be used to set a Default Requested Performing Location for the orderable item.  Prior to populating this column make sure that the proper pick lists and/or entries have been built in the Requested Performing Location dictionary.  This field will attempt to match on the name of the Requested Performing Location.
  
==Column Listing and Description==
+
*'''HCPCSCode''' - this field can be used to file a HCPCS code that may be associated with the orderable item.
 +
 
 +
*'''CPT4Code''' - this field can be used to file a CPT4 code that may be associated with the orderable item.  In this field only one value can be entered.
 +
 
 +
*'''ChargeCodeList''' - this field will allow you associate multiple CPT4 codes with the orderable item.  Multiple charge code entries must use a pipe "|" as a delimiter.
 +
 
 +
*'''When To Charge''' - this field is used to designate the charge behavior for the orderable item.
 +
 
 +
    *  Never - The order will never charge for the test.  This is used when the laboratory bills the patient
 +
      and you are not collecting any fees for the service other than normal office charges
 +
    *  On Order - This will create a charge as soon as the order is created.  This is typically illegal for a lab
 +
      result since you are not supposed to charge until the results are received and the test have actually been
 +
      performed.  In some cases the patient may never go to the lab or the tests results may never get returned.
 +
    *  Upon Completion  - this will create a charge as soon as the order has been completed. The completion
 +
      behavior is different based on the AutoCompleteFLAG
 +
    *  On Collection - This is used when your organization charges for blood draws or specimen collection.
 +
 
 +
*'''Comm Method Picklist''' - this field is used to assign a Communication Method Picklist to the orderable item.  Prior to loading this value make sure you have the appropriate picklist(s) defined in the Communication Method dictionary.  This field will match on the name of the picklist.  The "Diagnostic" picklist is one of the generic picklists delivered with the system.
 +
 
 +
*'''CommunicationMethod''' - this field is used to assign a default Communication Method to the orderable item.  This should correlate to a valid value that you have defined or included in the "Comm Method Picklist" (above).  This field also matches on the name of the Communication Method.  These are enforced entries that cannot be edited.  Available values for Communication Method are:
 +
 
 +
    *  Call Order
 +
    *  Perform Order
 +
    *  Print Requisition   
 +
    *  Record
 +
    *  Send to Performing Location
 +
 
 +
*'''Result Mnemonic''' - this is also limited to 10 characters (alpha-numeric).  If ever given only a code for an resultable item it is best practice to have the mnemonic value mirror the entry code value.
 +
 
 +
    Storage Location:  Works.dbo.QO_DE.EntryMnemonic
 +
    Data Type:  VarChar(10)
 +
    Possible Values:  Free Text
 +
 
 +
*'''Result Code''' - this is the unique identifier for the resultable item and is limited to 10 characters (alpha-numeric).  The result code is typically the primary identifier used for inbound result interface matching so be sure to honor the codes supplied to you by our LIS, RIS, or other 3rd party lab vendor.  If the test is being built as an In Office resultable item test or will not referenced in any interface then you may define your own naming convention for this field.
 +
 
 +
    Storage Location:  Works.dbo.QO_DE.EntryCode
 +
    Data Type:  VarChar(10)
 +
    Possible Values:  Free Text
 +
 
 +
*'''Result Name''' - this is the description for the resultable item as it will exist in the [[SSMT: RID - Resultable Item Dictionary|RID - Resultable Item Dictionary]].  If there is a separate display name desired or provided for the resultable item it may be specified in either the RID dictionary using the Display Name field.
 +
 
 +
    Storage Location:  Works.dbo.QO_DE.EntryName
 +
    Data Type:  VarChar(255)
 +
    Possible Values:  Free Text
 +
 
 +
*'''LOINCCode''' - this field will allow you to associate the given LOINC code to the orderable item.
 +
 
 +
*'''Answer Type''' - this field should always be set to "Numeric" for all laboratory results.  If a textual answer is sent it will be handled without causing an error upon filing.  It certain cases for compendiums such as Radiology it makes sense to go ahead and set this value to "Text".
  
 +
*'''SetOrder''' - this is the display order of the resultable item(s) as they will show in the EHR.  For example if a Lipid Profile contains 6 resultable items then you would want to define the set order as 0, 1, 2, 3, 4, 5, 6 in the spreadsheet.  This will allow you to assign a display order for each resultable item.  If you do not specify a display order then the default value is left as 0 and the display order will be assigned based on the order the items exist in the spreadsheet prior to loading (top to bottom).
  
 +
*'''ResultableSource''' - this column will allow you to set the method by which the resultable item can be resulted or populated in the context of the associated orderable.  Valid values for this column are:
  
 +
    *  User Only - This means that only a user can result the item.
 +
    *  Interface Only -  This means that the result can only be resulted from an interface transaction
 +
    *  User or Interface - This means that the result can be filed by an interface transaction or a user
  
 +
*'''InterfaceOnlyFlag''' - valid values for this field are the following:
  
'''back to [[SSMT]] main page'''
+
    *  Y - Yes
 +
    *  N - No
 +
    *  D - Deletes only if instance data is found

Latest revision as of 14:51, 28 November 2012

Description

The 'OrderResults-v11' content category allows you to define your orderable and resultable items and establish the appropriate relationship between them. Some orderable items such as labs may have one or more resultable items associated with them and some orderable items such as radiology typically have only one resultable item associated with them. The 'OrderResults-v11' content category allows you to set some basic context and populate some main fields associated with both orderable and resultable items. It is a key category that will help create the foundation for your Orderable Item dictionary and is typically derived from a compendium extract provided by your LIS, RIS, 3rd party lab vendor, or any diagnostic system that will be sending results or receiving orders from EHR.

Stored Procedures used:

  • Extracting data: ImpGetOrderANDResult
  • Loading data: ImpSetOrderAndResults

Column Listing and Description

  • Order Code - this is the unique identifier for the orderable item and is limited to 10 characters (alpha-numeric). The order code is typically the primary identifier used for inbound result interface matching and outbound order matching so be sure to honor the codes supplied to you by our LIS, RIS, or other 3rd party lab vendor. If the test is being built as an In Office test or not referenced in any interface then you may define your own naming convention for this field.
    Storage Location:  Works.dbo.Qo_Classification_DE.EntryCode
    Data Type:  VarChar(10)
    Possible Values:  Free Text
  • Order Name - this is the name of the orderable item and if no display name is defined in the OID - Orderable Item Dictionary then this will also function as the name displayed in the EHR.
   Storage Location:  Works.dbo.Qo_Classification_DE.EntryName
   Data Type:  VarChar(255)
   Possible Values:  Free Text
  • Order Mnemonic - this is also limited to 10 characters (alpha-numeric) and some external lab vendors actually define a short and meaningful alpha description for it. If ever given only a code for an orderable item it is best practice to have the mnemonic value mirror the entry code value.
   Storage Location:  Works.dbo.Qo_Classification_DE.EntryMnemonic
   Data Type:  VarChar(10)
   Possible Values:  Free Text
  • OrderingAuthority - this field designates a numeric value (1-10) and functions as an authentication value for ordering specific tests. The user must have an ordering authority set equal to or greater than that of the test in order to order the test. "1" is typically the default value for this field.
  • OIDMode - this column is intended to define the current state of the orderable item. Valid values for this field are:
   *  Active - This means the OID entry is active and available to users
   *  Draft - This means that the OID entry is editable in the dictionary, but users cannot see the entry.  
      This would be used if you were in the process of completing entries and didn't want them viewable.
   *  No Longer Used - This essentially means it's inactive. 
  • OrderType - this field correlates to the pre-delivered categories available for classifying orderable items. These values are basically the parent classes for the Parent Order Classification values (see below); they are the top levels in the OID hierarchy.
   *  Diagnostic Orders
   *  Imaging
   *  Supply
   *  Referral Orders
   *  Follow-Up Orders
   *  Lab
   *  Other
   *  Findings
   *  Patient Instructions
   *  Patient Precautions
  • Parent Order Classification - this field will determine where in the Orderable Item Dictionary's hierarchy the particular orderable item will be filed. This might be CT if the test is a Diagnostic Image or may be Microbiology is the test is a culture. One important consideration is that if you would like to store the orderable item in a classification or category that is not delivered with the system then it must exist prior to loading. This column will match on the name of the classification.
  • ItemType - for the purpose of loading your lab or rad compendium(s) this value should be set to "RESULTS". Possible values include:
   *  RESULTS
   *  FINDINGS
   *  OTHERS
  • OrderableSource - this column will allow you to set the method by which the orderable item can be created or ordered. Valid values for this column are:
   *  User Only - This means that only a user can request the order
   *  Interface Only -  This means that the order can only be requested from an interface transaction
   *  User or Interface - This means that an Order can be requested by an interface transaction or a user
   *  Recorded Only - This means that an Order can be documented only and would not be printed or sent to the interface
  • DefReqPerfLocation - this field can be used to set a Default Requested Performing Location for the orderable item. Prior to populating this column make sure that the proper pick lists and/or entries have been built in the Requested Performing Location dictionary. This field will attempt to match on the name of the Requested Performing Location.
  • HCPCSCode - this field can be used to file a HCPCS code that may be associated with the orderable item.
  • CPT4Code - this field can be used to file a CPT4 code that may be associated with the orderable item. In this field only one value can be entered.
  • ChargeCodeList - this field will allow you associate multiple CPT4 codes with the orderable item. Multiple charge code entries must use a pipe "|" as a delimiter.
  • When To Charge - this field is used to designate the charge behavior for the orderable item.
   *  Never - The order will never charge for the test.  This is used when the laboratory bills the patient 
      and you are not collecting any fees for the service other than normal office charges
   *  On Order - This will create a charge as soon as the order is created.  This is typically illegal for a lab 
      result since you are not supposed to charge until the results are received and the test have actually been 
      performed.  In some cases the patient may never go to the lab or the tests results may never get returned. 
   *  Upon Completion  - this will create a charge as soon as the order has been completed. The completion 
      behavior is different based on the AutoCompleteFLAG
   *  On Collection - This is used when your organization charges for blood draws or specimen collection.
  • Comm Method Picklist - this field is used to assign a Communication Method Picklist to the orderable item. Prior to loading this value make sure you have the appropriate picklist(s) defined in the Communication Method dictionary. This field will match on the name of the picklist. The "Diagnostic" picklist is one of the generic picklists delivered with the system.
  • CommunicationMethod - this field is used to assign a default Communication Method to the orderable item. This should correlate to a valid value that you have defined or included in the "Comm Method Picklist" (above). This field also matches on the name of the Communication Method. These are enforced entries that cannot be edited. Available values for Communication Method are:
   *  Call Order
   *  Perform Order
   *  Print Requisition    
   *  Record
   *  Send to Performing Location
  • Result Mnemonic - this is also limited to 10 characters (alpha-numeric). If ever given only a code for an resultable item it is best practice to have the mnemonic value mirror the entry code value.
   Storage Location:  Works.dbo.QO_DE.EntryMnemonic
   Data Type:  VarChar(10)
   Possible Values:  Free Text
  • Result Code - this is the unique identifier for the resultable item and is limited to 10 characters (alpha-numeric). The result code is typically the primary identifier used for inbound result interface matching so be sure to honor the codes supplied to you by our LIS, RIS, or other 3rd party lab vendor. If the test is being built as an In Office resultable item test or will not referenced in any interface then you may define your own naming convention for this field.
   Storage Location:  Works.dbo.QO_DE.EntryCode
   Data Type:  VarChar(10)
   Possible Values:  Free Text
  • Result Name - this is the description for the resultable item as it will exist in the RID - Resultable Item Dictionary. If there is a separate display name desired or provided for the resultable item it may be specified in either the RID dictionary using the Display Name field.
   Storage Location:  Works.dbo.QO_DE.EntryName
   Data Type:  VarChar(255)
   Possible Values:  Free Text
  • LOINCCode - this field will allow you to associate the given LOINC code to the orderable item.
  • Answer Type - this field should always be set to "Numeric" for all laboratory results. If a textual answer is sent it will be handled without causing an error upon filing. It certain cases for compendiums such as Radiology it makes sense to go ahead and set this value to "Text".
  • SetOrder - this is the display order of the resultable item(s) as they will show in the EHR. For example if a Lipid Profile contains 6 resultable items then you would want to define the set order as 0, 1, 2, 3, 4, 5, 6 in the spreadsheet. This will allow you to assign a display order for each resultable item. If you do not specify a display order then the default value is left as 0 and the display order will be assigned based on the order the items exist in the spreadsheet prior to loading (top to bottom).
  • ResultableSource - this column will allow you to set the method by which the resultable item can be resulted or populated in the context of the associated orderable. Valid values for this column are:
   *  User Only - This means that only a user can result the item.
   *  Interface Only -  This means that the result can only be resulted from an interface transaction
   *  User or Interface - This means that the result can be filed by an interface transaction or a user
  • InterfaceOnlyFlag - valid values for this field are the following:
   *  Y - Yes
   *  N - No 
   *  D - Deletes only if instance data is found